35 values · Used by 1 field
| Lookup Value | Definition | Status |
|---|
| Lookup Value | Definition | Status |
|---|---|---|
| Accessible Approach with Ramp AccessibleApproachWithRamp | A minimum of one entrance to the structure with clear, evenly-paved walkway from parking area or pedestrian arrival area; Path of travel does not... | Active |
| Accessible Bedroom AccessibleBedroom | Bedroom has adequate turnaround of 60 inches or other approved turnaround configuration; Closet doors have 32 inch clearance. Accessible... | Active |
| Accessible Central Living Area AccessibleCentralLivingArea | Hard surface flooring or low-pile carpet, securely attached along edges. Entrances to all rooms on all floors provide 36 inch clear passage. Multiple... | Active |
| Accessible Closets AccessibleClosets | Closet doors are 32” clearance throughout Central Living Area. | Active |
| Accessible Common Area AccessibleCommonArea | Common Area, used for entertaining guests, is level, with 36-inch passage through and around the space. Required to be considered Visitable. | Active |
| Accessible Doors AccessibleDoors | Minimum 32 inches clear passage; levered handle; threshold, if present, maximum 1/2-inch, but beveled on both sides when over 1/4 inch. Required to... | Active |
| Accessible Electrical and Environmental Controls AccessibleElectricalAndEnvironmentalControls | Thermostats and security system controls located on floor with central living area. Control devices for light switches and thermostats at 42-48... | Active |
| Accessible Elevator Installed AccessibleElevatorInstalled | Elevator with minimum 32" door and minimum 36" x 48" turning radius. | Active |
| Accessible Entrance AccessibleEntrance | Entrance door is a minimum of 32 inches wide; threshold , when present, maximum 1/2-inch, but when over 1/4-inch, is beveled on both sides. The entry... | Active |
| Accessible for Hearing-Impairment AccessibleForHearingImpairment | Home is wired for flashing lights and/or vibrating smoke alarm, door bell, other alerting features. | Active |
| Accessible Full Bath AccessibleFullBath | Bathroom has adequate turnaround: 60 inches or other approved turnaround configuration. Accessible bathing area: Roll-in shower or space for shower... | Active |
| Accessible Hallway(s) AccessibleHallways | Hallway is minimum 36, preferred 42 inches wide (or adequate alternative based on individual configuration). At least one lighting fixture is present. | Active |
| Accessible Kitchen AccessibleKitchen | 40" clear turn-around, or 36" clear with clear under-counter space for T-turn space in kitchen, unimpeded by fixtures. Roll-under/adaptable sink with... | Active |
| Accessible Kitchen Appliances AccessibleKitchenAppliances | Stove controls in front or side, at countertop height; Oven with side-access door at counter level; Microwave is at counter level. This is required... | Active |
| Accessible Stairway AccessibleStairway | Handrails on both sides of stairs, extended when possible, with shear force of 250 pounds. Interior and exterior stairs have adequate number of light... | Active |
| Accessible Washer/Dryer AccessibleWasherDryer | Raised clothes washer and/or dryer, front controls, side opening, both open to center. | Active |
| Adaptable Bathroom Walls AdaptableBathroomWalls | Reinforced main bathroom walls, including bath or shower, to permit installation of grab bars (with shear force of 250 pounds) and/or fixtures in the... | Active |
| Adaptable For Elevator AdaptableForElevator | Stacked closets in a multi-story house for possible future conversion to an elevator. | Active |
| Ceiling Track CeilingTrack | Track installed in ceiling for lift chair (Hoyer lift). | Active |
| Central Living Area CentralLivingArea | Central Living Area includes: Common Area, hallway(s), full or 3/4 bathroom, kitchen, at least one bedroom, access to environmental controls, and... | Active |
| Common Area CommonArea | The Common Area is the portion of the home near accessible entrance, used for entertaining guests. | Active |
| Customized Wheelchair Accessible CustomizedWheelchairAccessible | Customized accessibility for specific size or style of wheelchair or scooter. | Active |
| Electronic Environmental Controls ElectronicEnvironmentalControls | Programmable electronic controls for thermostat, lights, security system and automatic doors. | Active |
| Enhanced Accessible EnhancedAccessible | The Central Living Area is fully accessible for lifelong living by all residents, no matter their ability. A person in a wheelchair or with other... | Active |
| Exterior Wheelchair Lift ExteriorWheelchairLift | Mechanical wheelchair lift is installed outside the home to facilitate barrier-free approach. | Active |
| Grip-Accessible Features GripAccessibleFeatures | All doors, faucets and other mechanisms throughout central living area are lever, hands-free or other style that can be controlled with a closed,... | Active |
| Reinforced Floors ReinforcedFloors | Reinforced floors for bariatric needs, power wheelchairs, therapeutic tub or heavy medical equipment. | Active |
| Safe Emergency Egress from Home SafeEmergencyEgressFromHome | Minimum two, no-step, accessible egresses from Central Living Area. Window locks are 19 to 54 inches from the floor and can be opened with a closed... | Active |
| Smart Technology SmartTechnology | Smart Home (computer-controlled) and/or smart products— for example, voice activated controls, voice reminder, remote monitoring of individuals with... | Active |
| Stair Lift StairLift | Stair lift with motorized rail to climb interior or exterior stairway installed professionally. | Active |
| Standby Generator StandbyGenerator | Backup generator for refrigeration of medications, life-sustaining medical equipment or essential room temperature control. | Active |
| Therapeutic Whirlpool TherapeuticWhirlpool | Therapeutic whirlpool, properly installed. | Active |
| Visitable | The home is “visitable” for all guests: a person in a wheelchair can easily enter the home and access the main Common Area, a half-bathroom at... | Active |
| Visitor Bathroom VisitorBathroom | Bathroom that is closest to Common Area. Minimum half bath. Door has minimum 32-inch clear width opening; lever handles. Minimum 60-inch turnaround... | Active |
| Walker-Accessible Stairs WalkerAccessibleStairs | Treads are minimum 25 inches deep, with maximum 4 inches rise, minimum 36 inches wide. May be a custom feature in addition to approach with ramp. | Active |